1 x 16 PLC Fiber Splitter, Mini Module, 900μm, SC/APC, Singlemode
Blockless PLC splitter has stronger fiber protection than bare fiber splitter, which is a miniaturization result of cassette splitter. It’s mainly used for various connection and distribution boxes or network cabinets.
Package Style | Mini Module | Configuration Type | 1×16 |
Fiber Type | Singlemode | Connector Type | SC/APC |
Fiber Grade |
G.657A1
|
Input/Output Fiber Length | 1.5m |
Insertion Loss | ≤13.8dB | Return Loss | ≥ 55dB |
Loss Uniformity | ≤1.2dB | Directivity | ≥55dB |
Polarization Dependent Loss | ≤0.3dB | Temperature Dependent Loss | ≤0.5dB |
Wavelength Dependent Loss | ≤0.5dB | Operating Bandwidth | 1260~1650nm |
Split Ratio | 50/50 | Operating/Storage Temperature | -40~85°C |
Specifications 1×N PLC Splitter
Parameters | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | 1×128 |
Operating Wavelength(nm) | 1260~1650 | ||||||
Fiber Type | G657A1 or customer specified | ||||||
Insertion Loss (dB)(P/S Grade) | 3.8/4.0 | 7.1/7.3 | 10.2/10.5 | 13.5/13.7 | 16.5/16.9 | 20.5/21.0 | 23.8/24.2 |
Loss Uniformit(dB) | 0.4 | 0.6 | 0.8 | 1.2 | 1.5 | 2.0 | 2.5 |
Polarization Dependent Loss(dB) | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 0.35 | 0.4 |
Return Loss(dB)(P/S Grade) | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 |
Directivity(dB) | 55 | 55 | 55 | 55 | 55 | 55 | 55 |
Wavelength Dependent Loss(dB) | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Stability (-40~85℃)(dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 | 0.5 |
Operating Temperature(℃) | -40~+85 | ||||||
Storage Temperature(℃) | -40~+85 | ||||||
Device Dimension(mm) | 40×4×4 | 40×4×4 | 40×4×4 | 50×7×4 | 50×7×4 | 60×12×4 | N/A |
Module Dimension(mm) | 100×80×10 | 120×80×18 | 141×115×18 | ||||
Mini-Module Dimension(mm) | 50×7×4 | 60×12×4 | 80×20×6 | 100×40×6 | N/A |
Specifications 2×N PLC Splitter
Parameters | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | 2×128 |
Operating Wavelength(nm) | 1260~1650 | ||||||
Fiber Type | G657A1 or customer specified | ||||||
Insertion Loss (dB) P/S Grade) | 3.9/4/2 | 7.3/7.6 | 10.5/11 | 14.4/14.6 | 17.4/17.9 | 21.0/21.5 | 24.5/25.0 |
Loss Uniformity(dB) | ≤0.6 | ≤1.0 | ≤1.2 | ≤1.5 | ≤1.8 | ≤2.2 | ≤2.5 |
Polarization Dependent Loss(dB) | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.4 |
Return Loss(dB)(P/S Grade) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 |
Directivity(dB) | 55 | 55 | 55 | 55 | 55 | 55 | 55 |
Wavelength Dependent Loss(dB) | ≤0.3 | ≤0.4 | ≤0.5 | ≤0.5 | ≤0.5 | ≤0.5 | ≤0.5 |
Fiber Length (m) | 1.5(±0.1)or customer specified | ||||||
Temperature Stability(-40~85℃)(dB) | ≤0.5 | ||||||
Operating Temperature(℃) | -20~+75 | ||||||
Storage Temperature(℃) | -40~+85 | ||||||
Maximum Power Handling (mW) | 500 |
1、The above parameters were measured at room temperature, but not including connectors data.
2、Add an additional 0.2dB loss per connector,Return Loss≥55dB(APC),≥50dB(UPC).
Product Drawings:
Quality Assurance
Excellent quality is the foundation of Connlight’ s survival and development. Our operation team are experts with many years’ experiences in optical communication industry. Our manufacturers are first-class manufacturers in the industry. Many of them have the qualification of OEM for first-class system equipment manufacturers.